Structure 152660 · Fayette County, IA
Carries 200th ST over Volga River, 094103401.
22 ft end to end. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.
| State | Iowa |
| County | Fayette |
| Location | 094103401 |
| Carries | 200th ST |
| Crosses | Volga River |
| Coordinates | 42.92124, -92.01502 |
| Material | Steel |
| Design | Stringer/Multi-beam |
| Total Length | 21.7 ft (6.6 m) |
| Max Span | 20.0 ft (6.1 m) |
| Deck Width | 25.6 ft (7.8 m) |
| Deck Area | 51.5 sq m |
| Main Spans | 1 |
| Year Built | 1914 (reconstructed 1964) |
| Avg Daily Traffic | 33 (2022) |
| Lanes On Bridge | 2 |
| Last Inspection | October 2024 |
| Inspection Frequency | Every 24 months |
| Owner | County Highway Agency |
| Historical Significance | Bridge is possibly eligible (requires evaluation) |
| Scour Critical | 7 — Countermeasures installed |
| Structure Number | 000000000152660 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.