Structure 5501170 · Westchester County, NY

EB Coll.dist.907k over 907gx Midland Avenue 9

Carries EB Coll.dist.907k over 907gx Midland Avenue 9, Jct Of Rts Ccp & Brp.

Overall conditionFair

Set by its lowest-rated component: Deck and Substructure at 5 of 9.

How ratings work
Decksets the rating5/9 · Fair
Superstructure6/9 · Satisfactory
Substructuresets the rating5/9 · Fair
Channelnot part of overall7/9 · Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT1,037 FT OVERALL200 FT0ELEVATION · LENGTHS TO SCALE
Deck 5/9 · sets the ratingSuperstructure 6/9Substructure 5/9 · sets the rating

1,037 ft end to end, longest span 139 ft: about 2.9 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.

Built197056 years old
Length1037.1 ft316.1 m
Last inspectedAugust 2024every 24 months

Location

StateNew York
CountyWestchester
LocationJct Of Rts Ccp & Brp
CarriesEB Coll.dist.907k
Crosses907gx Midland Avenue 9
Coordinates40.92770, -73.84024

Physical Characteristics

MaterialSteel
DesignStringer/Multi-beam
Total Length1037.1 ft (316.1 m)
Max Span138.8 ft (42.3 m)
Deck Width35.4 ft (10.8 m)
Deck Area3413.9 sq m
Main Spans8
Year Built1970

Traffic

Truck Traffic2%
Lanes On Bridge2
Lanes Under Bridge14

Inspection & Ownership

Last InspectionAugust 2024
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour Critical5 — Stable for scour
Structure Number000000005501170

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.

Nearby Bridges