Structure 2265210 · Westchester County, NY
Carries Fenimore Road over Pipe Line Road Mnrr Ha, 0.1 Mi W Brp Exit 15.
Set by its lowest-rated component: Deck and Substructure at 6 of 9.
How ratings work126 ft end to end, longest span 66 ft. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a box-beam bridge.
| State | New York |
| County | Westchester |
| Location | 0.1 Mi W Brp Exit 15 |
| Carries | Fenimore Road |
| Crosses | Pipe Line Road Mnrr Ha |
| Coordinates | 41.01035, -73.79631 |
| Material | Prestressed Concrete Continuous |
| Design | Box Beam - Multiple |
| Total Length | 126.0 ft (38.4 m) |
| Max Span | 65.9 ft (20.1 m) |
| Deck Width | 40.4 ft (12.3 m) |
| Deck Area | 472.3 sq m |
| Main Spans | 2 |
| Year Built | 1912 (reconstructed 1987) |
| Avg Daily Traffic | 13,794 (2010) |
| Truck Traffic | 4% |
| Lanes On Bridge | 2 |
| Lanes Under Bridge | 2 |
| Last Inspection | August 2023 |
| Inspection Frequency | Every 24 months |
| Owner | Railroad |
| Historical Significance | Historical significance is not determined |
| Scour Critical | Not applicable |
| Structure Number | 000000002265210 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.