Structure 39141 · Philadelphia County, PA
Carries Green Lane over Schuyl Rv Nsrc Manayk Cn, W Of Main Street 16g12.
Set by its lowest-rated component: Deck and Superstructure and Substructure at 5 of 9.
How ratings work601 ft end to end, longest span 93 ft: about 1.7 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a deck arch.
| State | Pennsylvania |
| County | Philadelphia |
| Location | W Of Main Street 16g12 |
| Carries | Green Lane |
| Crosses | Schuyl Rv Nsrc Manayk Cn |
| Coordinates | 40.02675, -75.22736 |
| Material | Concrete |
| Design | Arch - Deck |
| Total Length | 601.0 ft (183.2 m) |
| Max Span | 92.8 ft (28.3 m) |
| Deck Width | 56.1 ft (17.1 m) |
| Deck Area | 3132.7 sq m |
| Main Spans | 4 |
| Year Built | 1928 |
| Avg Daily Traffic | 20,000 (1981) |
| Lanes On Bridge | 2 |
| Last Inspection | September 2023 |
| Inspection Frequency | Every 24 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is on the National Register of Historic Places |
| Scour Critical | 4 — Foundations need monitoring |
| Structure Number | 000000000039141 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.