Structure 8729581 · Wood County, OH

I80 Ohio Tpk over Cr10-csx Tran Rr

Carries I80 Ohio Tpk over Cr10-csx Tran Rr, 2.9mi West Of Exit 71.

Overall conditionFair

Set by its lowest-rated component: Superstructure at 5 of 9.

How ratings work
Deck8/9 · Very Good
Superstructuresets the rating5/9 · Fair
Substructure7/9 · Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT307 FT OVERALL50 FT0ELEVATION · LENGTHS TO SCALE
Deck 8/9Superstructure 5/9 · sets the ratingSubstructure 7/9

307 ft end to end, longest span 61 ft: about 4 semi-trucks nose to tail. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.

Built1954rebuilt 1988
Length307.1 ft93.6 m
Daily traffic31,648counted 2015
Last inspectedMarch 2024every 12 months

Location

StateOhio
CountyWood
Location2.9mi West Of Exit 71
CarriesI80 Ohio Tpk
CrossesCr10-csx Tran Rr
Coordinates41.53991, -83.51136

Physical Characteristics

MaterialSteel Continuous
DesignStringer/Multi-beam
Total Length307.1 ft (93.6 m)
Max Span61.0 ft (18.6 m)
Deck Width126.0 ft (38.4 m)
Deck Area3594.2 sq m
Main Spans6
Year Built1954 (reconstructed 1988)

Traffic

Avg Daily Traffic31,648 (2015)
Truck Traffic27%
Lanes On Bridge6
Lanes Under Bridge2

Inspection & Ownership

Last InspectionMarch 2024
Inspection FrequencyEvery 12 months
OwnerState Toll Authority
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number8729581

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.