Structure 180570237403160 · Dallas County, TX
Carries IH 20 EB Conn F over Drainage Ditch, 0.1 Mi E Of IH 20.
A culvert 24 ft across with 3 openings. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights, so those are drawn as typical for a culvert.
| State | Texas |
| County | Dallas |
| Location | 0.1 Mi E Of IH 20 |
| Carries | IH 20 EB Conn F |
| Crosses | Drainage Ditch |
| Coordinates | 32.69023, -96.63097 |
| Material | Concrete |
| Design | Culvert |
| Total Length | 24.0 ft (7.3 m) |
| Max Span | 6.9 ft (2.1 m) |
| Deck Area | 53.3 sq m |
| Main Spans | 3 |
| Year Built | 1971 |
| Avg Daily Traffic | 10,100 (2013) |
| Truck Traffic | 13% |
| Lanes On Bridge | 1 |
| Last Inspection | October 2023 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is possibly eligible (requires evaluation) |
| Scour Critical | 8 — Stable, low risk |
| Structure Number | 180570237403160 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.