Structure 180570019603453 · Dallas County, TX

Ih35e Nb/pgbt WB over Pgbt Ml

Carries Ih35e Nb/pgbt WB over Pgbt Ml, IH 35e/sh 190 Interchange.

Overall conditionFair

Set by its lowest-rated component: Deck and Superstructure at 6 of 9.

How ratings work
Decksets the rating6/9 · Satisfactory
Superstructuresets the rating6/9 · Satisfactory
Substructure7/9 · Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT1,917 FT OVERALL250 FT0ELEVATION · LENGTHS TO SCALE
Deck 6/9 · sets the ratingSuperstructure 6/9 · sets the ratingSubstructure 7/9

1,917 ft end to end, longest span 250 ft: about 5.3 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.

Built200422 years old
Length1917.0 ft584.3 m
Daily traffic10,000counted 2011
Last inspectedApril 2024every 24 months

Location

StateTexas
CountyDallas
LocationIH 35e/sh 190 Interchange
CarriesIh35e Nb/pgbt WB
CrossesPgbt Ml
Coordinates32.98185, -96.93082

Physical Characteristics

MaterialSteel Continuous
DesignStringer/Multi-beam
Total Length1917.0 ft (584.3 m)
Max Span250.0 ft (76.2 m)
Deck Width27.9 ft (8.5 m)
Deck Area4966.6 sq m
Main Spans4
Year Built2004

Traffic

Avg Daily Traffic10,000 (2011)
Lanes On Bridge1
Lanes Under Bridge17

Inspection & Ownership

Last InspectionApril 2024
Inspection FrequencyEvery 24 months
OwnerLocal Toll Authority
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number180570019603453

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.