Structure 53 1213 · Los Angeles County, CA

Interstate 110 over Dominguez Channel

Carries Interstate 110 over Dominguez Channel, 07-la-110-9.13-la.

Overall conditionFair

Set by its lowest-rated component: Substructure at 6 of 9.

How ratings work
Deck7/9 · Good
Superstructure7/9 · Good
Substructuresets the rating6/9 · Satisfactory
Channelnot part of overall8/9 · Very Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT311 FT OVERALL50 FT0ELEVATION · LENGTHS TO SCALE
Deck 7/9Superstructure 7/9Substructure 6/9 · sets the rating

311 ft end to end, longest span 104 ft: about 4 semi-trucks nose to tail. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.

Built1960rebuilt 1985
Length311.0 ft94.8 m
Daily traffic273,760counted 2022
Last inspectedApril 2024every 24 months

Location

StateCalifornia
CountyLos Angeles
Location07-la-110-9.13-la
CarriesInterstate 110
CrossesDominguez Channel
Coordinates33.86188, -118.28475

Physical Characteristics

MaterialPrestressed Concrete Continuous
DesignStringer/Multi-beam
Total Length311.0 ft (94.8 m)
Max Span104.0 ft (31.7 m)
Deck Width165.4 ft (50.4 m)
Deck Area4777.9 sq m
Main Spans3
Year Built1960 (reconstructed 1985)

Traffic

Avg Daily Traffic273,760 (2022)
Truck Traffic6%
Lanes On Bridge10

Inspection & Ownership

Last InspectionApril 2024
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour Critical5 — Stable for scour
Structure Number53 1213

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.