Structure 5502101 · Miami County, OH
Carries Ir-75 over W. Branch Of Peters Cree, .57mi.s. Of Jct. Sr-55.
A culvert 21 ft across with 2 openings. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights, so those are drawn as typical for a culvert.
| State | Ohio |
| County | Miami |
| Location | .57mi.s. Of Jct. Sr-55 |
| Carries | Ir-75 |
| Crosses | W. Branch Of Peters Cree |
| Coordinates | 40.01693, -84.23041 |
| Material | Steel |
| Design | Culvert |
| Total Length | 21.0 ft (6.4 m) |
| Max Span | 8.9 ft (2.7 m) |
| Deck Area | 249.6 sq m |
| Main Spans | 2 |
| Year Built | 1957 |
| Avg Daily Traffic | 66,840 (2015) |
| Truck Traffic | 12% |
| Lanes On Bridge | 4 |
| Last Inspection | July 2024 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Scour Critical | 8 — Stable, low risk |
| Structure Number | 5502101 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.