Structure H207 · Graham County, AZ
Carries IRR BIA RTE 103 over San Carlos River, 3.7 Km S Of San Carlos.
Set by its lowest-rated component: Deck and Superstructure and Substructure at 7 of 9.
How ratings work810 ft end to end, longest span 116 ft: about 2.3 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.
| State | Arizona |
| County | Graham |
| Location | 3.7 Km S Of San Carlos |
| Carries | IRR BIA RTE 103 |
| Crosses | San Carlos River |
| Coordinates | 33.32275, -110.44661 |
| Material | Prestressed Concrete |
| Design | Stringer/Multi-beam |
| Total Length | 810.0 ft (246.9 m) |
| Max Span | 116.5 ft (35.5 m) |
| Deck Width | 37.1 ft (11.3 m) |
| Deck Area | 2790.0 sq m |
| Main Spans | 7 |
| Year Built | 1989 |
| Avg Daily Traffic | 3,000 (2024) |
| Truck Traffic | 5% |
| Lanes On Bridge | 2 |
| Last Inspection | January 2024 |
| Inspection Frequency | Every 24 months |
| Owner | Bureau of Indian Affairs |
| Historical Significance | Bridge is not eligible for the National Register |
| Scour Critical | 8 — Stable, low risk |
| Structure Number | 00000000000H207 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.