Structure PUEJKSN-0.0-ADM · Pueblo County, CO
Carries Jackson St. over Bessemer Ditch, Corner Of Jackson/adam.
A culvert 22 ft across. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights, so those are drawn as typical for a culvert.
| State | Colorado |
| County | Pueblo |
| Location | Corner Of Jackson/adam |
| Carries | Jackson St. |
| Crosses | Bessemer Ditch |
| Coordinates | 38.25556, -104.63135 |
| Material | Concrete |
| Design | Culvert |
| Total Length | 22.0 ft (6.7 m) |
| Max Span | 22.0 ft (6.7 m) |
| Deck Width | 52.5 ft (16 m) |
| Deck Area | 107.2 sq m |
| Main Spans | 1 |
| Year Built | 1933 (reconstructed 1973) |
| Avg Daily Traffic | 2,732 (2021) |
| Truck Traffic | 5% |
| Lanes On Bridge | 2 |
| Last Inspection | November 2024 |
| Inspection Frequency | Every 24 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Historical significance is not determined |
| Scour Critical | 8 — Stable, low risk |
| Structure Number | PUEJKSN-0.0-ADM |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."