Structure 53C0706 · Los Angeles County, CA
Carries Leadora AVE over Little Dalton Wash, 1.3mi E/o Grand AVE.
A culvert 25 ft across. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights, so those are drawn as typical for a culvert.
| State | California |
| County | Los Angeles |
| Location | 1.3mi E/o Grand AVE |
| Carries | Leadora AVE |
| Crosses | Little Dalton Wash |
| Coordinates | 34.14328, -117.85102 |
| Material | Concrete |
| Design | Culvert |
| Total Length | 24.9 ft (7.6 m) |
| Max Span | 22.3 ft (6.8 m) |
| Deck Width | 50.9 ft (15.5 m) |
| Deck Area | 117.8 sq m |
| Main Spans | 1 |
| Year Built | 1961 |
| Avg Daily Traffic | 1,849 (2013) |
| Truck Traffic | 2% |
| Lanes On Bridge | 2 |
| Last Inspection | January 2023 |
| Inspection Frequency | Every 48 months |
| Owner | City/Municipal Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Scour Critical | 8 — Stable, low risk |
| Structure Number | 53C0706 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.