Structure 33 0371G · Alameda County, CA

N680-w580e580-n680 over E580-n680 580 N680-w580

Carries N680-w580e580-n680 over E580-n680 580 N680-w580, 04-ala-680-r20.03-ple.

Overall conditionGood

Set by its lowest-rated component: Deck and Superstructure and Substructure at 7 of 9.

How ratings work
Decksets the rating7/9 · Good
Superstructuresets the rating7/9 · Good
Substructuresets the rating7/9 · Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT325 FT OVERALL50 FT0ELEVATION · LENGTHS TO SCALE
Deck 7/9Superstructure 7/9Substructure 7/9

325 ft end to end, longest span 85 ft: about 5 semi-trucks nose to tail. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for an orthotropic-deck bridge.

Built196561 years old
Length325.1 ft99.1 m
Daily traffic22,700counted 2009
Last inspectedApril 2024every 24 months

Location

StateCalifornia
CountyAlameda
Location04-ala-680-r20.03-ple
CarriesN680-w580e580-n680
CrossesE580-n680 580 N680-w580
Coordinates37.70109, -121.92242

Physical Characteristics

MaterialSteel
DesignOrthotropic
Total Length325.1 ft (99.1 m)
Max Span85.0 ft (25.9 m)
Deck Width34.1 ft (10.4 m)
Deck Area1030.6 sq m
Main Spans4
Year Built1965

Traffic

Avg Daily Traffic22,700 (2009)
Truck Traffic8%
Lanes On Bridge2
Lanes Under Bridge10

Inspection & Ownership

Last InspectionApril 2024
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number33 0371G

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.

Nearby Bridges