Structure 62103000016110 · Pend Oreille County, WA
Carries No Data Entered over W Branch Leclerc 19.7, No Data Entered.
A culvert 25 ft across. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights, so those are drawn as typical for a culvert.
| State | Washington |
| County | Pend Oreille |
| Location | No Data Entered |
| Carries | No Data Entered |
| Crosses | W Branch Leclerc 19.7 |
| Coordinates | 48.65672, -117.23901 |
| Material | Steel |
| Design | Culvert |
| Total Length | 24.9 ft (7.6 m) |
| Max Span | 24.9 ft (7.6 m) |
| Deck Area | 37.2 sq m |
| Main Spans | 1 |
| Year Built | 2005 |
| Avg Daily Traffic | 50 |
| Lanes On Bridge | 1 |
| Last Inspection | October 2022 |
| Inspection Frequency | Every 48 months |
| Owner | U.S. Forest Service |
| Historical Significance | Historical significance is not determined |
| Scour Critical | 5 — Stable for scour |
| Structure Number | 062103000016110 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.