Structure 55 0770F · Orange County, CA

S133-barranca PKWY over S5-s133 Connector Ramp

Carries S133-barranca PKWY over S5-s133 Connector Ramp, 12-ora-133-m9.35-irvn.

Overall conditionFair

Set by its lowest-rated component: Substructure at 6 of 9.

How ratings work
Deck7/9 · Good
Superstructure7/9 · Good
Substructuresets the rating6/9 · Satisfactory
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT516 FT OVERALL100 FT0ELEVATION · LENGTHS TO SCALE
Deck 7/9Superstructure 7/9Substructure 6/9 · sets the rating

516 ft end to end, longest span 150 ft: about 7 semi-trucks nose to tail. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a box-beam bridge.

Built199630 years old
Length516.1 ft157.3 m
Daily traffic3,872counted 2015
Last inspectedJanuary 2025every 24 months

Location

StateCalifornia
CountyOrange
Location12-ora-133-m9.35-irvn
CarriesS133-barranca PKWY
CrossesS5-s133 Connector Ramp
Coordinates33.66446, -117.75421

Physical Characteristics

MaterialPrestressed Concrete Continuous
DesignBox Beam - Single/Spread
Total Length516.1 ft (157.3 m)
Max Span149.9 ft (45.7 m)
Deck Width27.6 ft (8.4 m)
Deck Area1321.3 sq m
Main Spans4
Year Built1996

Traffic

Avg Daily Traffic3,872 (2015)
Truck Traffic3%
Lanes On Bridge1
Lanes Under Bridge2

Inspection & Ownership

Last InspectionJanuary 2025
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number55 0770F

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.