Structure 55 0413F · Orange County, CA

S405-n605 Conn over RTE 405 605 Conn Riv

Carries S405-n605 Conn over RTE 405 605 Conn Riv, 12-ora-405-24.11-slb.

Overall conditionFair

Set by its lowest-rated component: Substructure at 5 of 9.

How ratings work
Deck7/9 · Good
Superstructure7/9 · Good
Substructuresets the rating5/9 · Fair
Channelnot part of overall8/9 · Very Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT1,796 FT OVERALL250 FT0ELEVATION · LENGTHS TO SCALE
Deck 7/9Superstructure 7/9Substructure 5/9 · sets the rating

1,796 ft end to end, longest span 123 ft: about 5.0 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a box-beam bridge.

Built196660 years old
Length1795.9 ft547.4 m
Daily traffic22,800counted 2014
Last inspectedSeptember 2023every 24 months

Location

StateCalifornia
CountyOrange
Location12-ora-405-24.11-slb
CarriesS405-n605 Conn
CrossesRTE 405 605 Conn Riv
Coordinates33.78646, -118.08978

Physical Characteristics

MaterialConcrete Continuous
DesignBox Beam - Multiple
Total Length1795.9 ft (547.4 m)
Max Span123.0 ft (37.5 m)
Deck Width34.1 ft (10.4 m)
Deck Area5693.0 sq m
Main Spans17
Year Built1966

Traffic

Avg Daily Traffic22,800 (2014)
Truck Traffic3%
Lanes On Bridge2
Lanes Under Bridge19

Inspection & Ownership

Last InspectionSeptember 2023
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour Critical3 — Scour critical
Structure Number55 0413F

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.