Structure 37 0414S · Santa Clara County, CA

Santa Teresa-nb 87 over Chynoweth Avenue

Carries Santa Teresa-nb 87 over Chynoweth Avenue, 04-scl-087-0.20-sjs.

Overall conditionGood

Set by its lowest-rated component: Deck and Superstructure and Substructure at 7 of 9.

How ratings work
Decksets the rating7/9 · Good
Superstructuresets the rating7/9 · Good
Substructuresets the rating7/9 · Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT198 FT OVERALL25 FT0ELEVATION · LENGTHS TO SCALE
Deck 7/9Superstructure 7/9Substructure 7/9

198 ft end to end, longest span 98 ft: about 3 semi-trucks nose to tail. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a box-beam bridge.

Built199135 years old
Length197.5 ft60.2 m
Daily traffic5,000counted 1998
Last inspectedApril 2021every 48 months

Location

StateCalifornia
CountySanta Clara
Location04-scl-087-0.20-sjs
CarriesSanta Teresa-nb 87
CrossesChynoweth Avenue
Coordinates37.25965, -121.85832

Physical Characteristics

MaterialPrestressed Concrete Continuous
DesignBox Beam - Multiple
Total Length197.5 ft (60.2 m)
Max Span98.1 ft (29.9 m)
Deck Width48.2 ft (14.7 m)
Deck Area884.9 sq m
Main Spans2
Year Built1991

Traffic

Avg Daily Traffic5,000 (1998)
Truck Traffic3%
Lanes On Bridge2
Lanes Under Bridge4

Inspection & Ownership

Last InspectionApril 2021
Inspection FrequencyEvery 48 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number37 0414S

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.