Structure 22200035303459 · Tarrant County, TX

Sh114wb/int Pky SB over SH 114 & Intl PKWY

Carries Sh114wb/int Pky SB over SH 114 & Intl PKWY, Sh114-121 Split @ Dfw.

Overall conditionGood

Set by its lowest-rated component: Deck and Substructure at 7 of 9.

How ratings work
Decksets the rating7/9 · Good
Superstructure8/9 · Very Good
Substructuresets the rating7/9 · Good
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT2,427 FT OVERALL500 FT0ELEVATION · LENGTHS TO SCALE
Deck 7/9 · sets the ratingSuperstructure 8/9Substructure 7/9 · sets the rating

2,427 ft end to end, longest span 125 ft: about 6.7 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.

Built201214 years old
Length2427.2 ft739.8 m
Daily traffic16,000counted 2010
Last inspectedMay 2022every 48 months

Location

StateTexas
CountyTarrant
LocationSh114-121 Split @ Dfw
CarriesSh114wb/int Pky SB
CrossesSH 114 & Intl PKWY
Coordinates32.93424, -97.03725

Physical Characteristics

MaterialPrestressed Concrete
DesignStringer/Multi-beam
Total Length2427.2 ft (739.8 m)
Max Span125.0 ft (38.1 m)
Deck Width44.9 ft (13.7 m)
Deck Area10135.3 sq m
Main Spans19
Year Built2012

Traffic

Avg Daily Traffic16,000 (2010)
Truck Traffic1%
Lanes On Bridge1
Lanes Under Bridge19

Inspection & Ownership

Last InspectionMay 2022
Inspection FrequencyEvery 48 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number022200035303459

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.