Structure 480180 · Escambia County, FL
Carries Sr4 over Escambia River, 1.5mi. East Of Sr95 Us29.
Set by its lowest-rated component: Deck and Superstructure and Substructure at 7 of 9.
How ratings work6,128 ft end to end, longest span 60 ft: about 17 football fields, or 1.2 miles. Lengths are drawn to scale; at this length a semi-truck would be a speck. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.
| State | Florida |
| County | Escambia |
| Location | 1.5mi. East Of Sr95 Us29 |
| Carries | Sr4 |
| Crosses | Escambia River |
| Coordinates | 30.96457, -87.23620 |
| Material | Prestressed Concrete |
| Design | Stringer/Multi-beam |
| Total Length | 6127.6 ft (1867.7 m) |
| Max Span | 60.0 ft (18.3 m) |
| Deck Width | 46.9 ft (14.3 m) |
| Deck Area | 26708.1 sq m |
| Main Spans | 102 |
| Year Built | 1994 |
| Avg Daily Traffic | 4,900 (2022) |
| Truck Traffic | 13% |
| Lanes On Bridge | 2 |
| Last Inspection | December 2023 |
| Inspection Frequency | Every 24 months |
| Owner | State Highway Agency |
| Historical Significance | Bridge is not eligible for the National Register |
| Scour Critical | 8 — Stable, low risk |
| Structure Number | 480180 |
Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."
A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.