Structure 22904240800002 · Lafourche County, LA

Us0090 over La 316

Carries Us0090 over La 316, US 90 Over La 316.

Overall conditionFair

Set by its lowest-rated component: Deck and Substructure at 6 of 9.

How ratings work
Decksets the rating6/9 · Satisfactory
Superstructure7/9 · Good
Substructuresets the rating6/9 · Satisfactory
0 failed4 poor6 fair9 excellent

Elevation

Side view, colored by inspection rating
SEMI-TRUCK · 72 FT2,240 FT OVERALL250 FT0ELEVATION · LENGTHS TO SCALE
Deck 6/9 · sets the ratingSuperstructure 7/9Substructure 6/9 · sets the rating

2,240 ft end to end, longest span 90 ft: about 6.2 football fields. Lengths and the semi-truck on the deck are drawn to the same scale. Each part is colored by its latest inspection rating. The inventory records lengths but not heights or the layout of the shorter spans, so those are drawn as typical for a multi-beam bridge.

Built198046 years old
Length2240.2 ft682.8 m
Daily traffic11,400counted 2016
Last inspectedJune 2024every 24 months

Location

StateLouisiana
CountyLafourche
LocationUS 90 Over La 316
CarriesUs0090
CrossesLa 316
Coordinates29.68313, -90.74727

Physical Characteristics

MaterialPrestressed Concrete Continuous
DesignStringer/Multi-beam
Total Length2240.2 ft (682.8 m)
Max Span89.9 ft (27.4 m)
Deck Width42.7 ft (13 m)
Deck Area8876.4 sq m
Main Spans27
Year Built1980

Traffic

Avg Daily Traffic11,400 (2016)
Truck Traffic18%
Lanes On Bridge2
Lanes Under Bridge4

Inspection & Ownership

Last InspectionJune 2024
Inspection FrequencyEvery 24 months
OwnerState Highway Agency
Historical SignificanceBridge is not eligible for the National Register
Scour CriticalNot applicable
Structure Number022904240800002

How Bridge Ratings Work

Inspectors rate each major part of a bridge (the deck you drive on, the superstructure of beams that holds it up, and the substructure of piers and abutments beneath) on a 0–9 scale. A bridge's overall condition is its lowest of those ratings, so one deteriorated component makes the whole bridge "poor."

0Failed
1Imminent failure
2Critical
3Serious
4Poor
5Fair
6Satisfactory
7Good
8Very good
9Excellent
Good · lowest component 7–9
Fair · lowest component 5–6
Poor · lowest component 0–4

A poor rating is not a closure. It means the bridge is flagged for priority repair or replacement; bridges judged unsafe are closed or posted with weight limits. The waterway (channel) rating is reported, but it does not count toward the overall classification.